Basically
all formations penetrated
during drilling are porous
and permeable to some
degree.
Fluids contained in pore
spaces are under pressure
that is overbalanced by the
drilling fluid pressure in
the well bore.
The borehole pressure is
equal to the hydrostatic
pressure plus the friction
pressure loss in the
annulus. If for some reason
the borehole pressure falls
below the formation fluid
pressure, the formation
fluids can enter the well.
Such an event is known as a
kick. This name is
associated with a rather
sudden flowrate increase
observed at the surface.
A formation fluid influx (a
kick) may result from one of
the following
reasons:
• abnormally high formation
pressure is encountered
• lost circulation mud
weight too low
• swabbing in during
tripping operations
• not filling up the hole
while pulling out the drill
string
• recirculating gas or oil
cut mud.
If a kick is not controlled
properly, a blowout will
occur.
A blowout may develop for
one or more of the following
causes:
• lack of analysis of data
obtained from offset wells
• lack or misunderstanding
of data during drilling
• malfunction or even lack
of adequate well control
equipment |
|
SURFACE
EQUIPMENT
A formation gas or fluid kick can be
efficiently and safely controlled if
the proper equipment is installed at
the surface. One of several possible
arrangement of pressure control
equipment . The blowout preventer
(BOP) stack consists of a spherical
preventer (i.e.,Hydril) and ram type
BOPs with blind rams in one and pipe
rams in another with
a drilling spool placed in the
stack.
A spherical preventer contains a
packing element that seals the space
around the outside of the drill
pipe. This preventer is not designed
to shut off the well when the drill
pipe is out of the hole. The
spherical preventer allows stripping
operations and some limited pipe
rotation.
Hydril
Corporation, Shaffer, and other
manufactures provide several models
with differing packing element
designs for specific types of
service. The ram type preventer uses
two concentric halves to close and
seal around the pipe, called pipe
rams or blind rams, which seal
against the opposing half when there
is no pipe in the hole. Some pipe
rams will only seal on a single size
pipe; 5 in. pipe rams only seal
around 5 in. drill pipe. There are
also variable bore rams, which cover
a specific size range such as 312
in. to 5 in. that seal on any size
pipe in their range.
Care must be taken before closing
the blind rams. If pipe is in the
hole and the blind rams are closed,
the pipe may be damaged or cut. A
special type of blind rams that will
sever the pipe are called shear
blind rams.
These rams will seal against
themselves when there is no pipe in
the hole, or, in the case of pipe in
the hole, the rams will first shear
the pipe and then
continue to close until they seal
the well. A drilling spool is the
element of the BOP stack to which
choke and kill lines are attached.
The pressure rating of the drilling
spool and its side outlets should be
consistent with BOP stack. The kill
line allows pumping mud into the
annulus of the well in the case that
is required. The choke
line side is connected to a manifold
to enable circulation of drilling
and formation fluids out of the hole
in a controlled manner.
A degasser is installed on the mud
return line to remove any small
amounts of entrained gas in the
returning drilling fluids. Samples
of gas
are analyzed using the gas
chromatograph.
If for some reason the well cannot
be shut in, and thus prevents
implementation of regular kick
killing procedure, a diverter type
stack is used rather, the BOP stack
described above. The diverter stack
is furnished with a blow-down line
to allow the well to vent wellbore
gas or fluids a safe distance away
from the rig.
WHEN AND HOW
TO CLOSE THE WELL
While drilling, there are certain
warning signals that, if properly
analyzed, can lead to early
detection of gas or formation fluid
entry into the wellbore.
1. Drilling break. A relatively
sudden increase in the drilling rate
is called a drilling break. The
drilling break may occur due to a
decrease in the difference between
borehole pressure and formation
pressure. When a drilling break is
observed, the pumps should be
stopped and the well watched for
flow at the mud line. If the well
does not flow, it probably means
that the overbalance is not lost or
simply that a softer formation has
be encountered.
2. Decrease in pump pressure. When
less dense formation fluid enters
the borehole, the hydrostatic head
in the annulus is decreased.
Although reduction in pump pressure
may be caused by several other
factors, drilling personnel should
consider a formation fluid influx
into the wellbore as one possible
cause. The pumps should be stopped
and the return flow mud line watched
carefully.
3. Increase in pit level. This is a
definite signal of formation fluid
invasion into the wellbore. The well
must be shut in as soon as possible.
4. Gas-cut mud. When drilling
through gas-bearing formations,
small quantities of gas occur in the
cuttings. As these cuttings are
circulated up, the annulus, the gas
expands. The resulting reduction in
mud weight is observed at surface.
Stopping the pumps and observing the
mud return line help determine
whether the overbalance is lost.
If the kick is gained while
tripping, the only warning signal we
have is an increase in fluid volume
at the surface (pit gain). Once it
is determined that the pressure
overbalance is lost, the well must
be closed as quickly as possible.
The sequence of operations in
closing a well is as follows:
1. Shut off the mud pumps.
2. Raise the Kelly above the BOP
stack.
3. Open the choke line
4. Close the spherical preventer.
5. Close the choke slowly.
6. Record the pit level increase.
7. Record the stabilized pressure on
the drill pipe (Stand Pipe) and
annulus pressure gauges.
8. Notify the company personnel.
9. Prepare the kill procedure.
If the well kicks while tripping,
the sequence of necessary steps can
be given below:
1. Close the
safety valve (Kelly cock) on the
drill pipe.
2. Pick up and install the Kelly or
top drive.
3. Open the safety valve (Kelly
cock).
4. Open the choke line.
5. Close the annular (spherical)
preventer.
6. Record the pit gain along with
the shut in drill pipe pressure (SIDPP)
and shut in casing pressure (SICP).
7. Notify the company personnel.
8. Prepare the kill procedure.
Depending on the type of drilling
rig and company policy, this
sequence of operations may be
changed.